CL-GE300 Rev.900-580-31-00
8.3. Example 3: Multiple Cameras/Synchronizing Cameras
RJ- 45 12pin
Camera 1
MONO
8bit
CL- GE300
C
L1 I
N
CL2INCL3 IN
GigE
Trigger IN0
Camera 2
MONO
8bit
Camera 3
MONO
8bit
Trigger IN0
Camera 1 OUT
Camera 2 OUT
Camera 3 OUT
Camera 3 OUT
GigE OUT
FIFO FIFOFIFO
Camera 2 OUT
Camera 1 OUT
Exposure Time
(Camera side: MONO 8bit output, Trigger input: Trigger IN 0 input)
Recommended
cameras
:
VCC-G22/F22PCL series,VCC-G32/F32PCL (RAW mode) series
Conditions :
・Select RAW output cameras when using color cameras.
RGB output cameras shall not be connected.
・Cameras with same pixels and same frame rate shall be selected.
・Different triggers cannot be input. Also, different shutter values cannot
be set either.
Camera settings
Address Data Remarks
Camera side
Set the camera to trigger mode.
(Refer to the Specifications, address settings for the details.)
When using VCC-G22/F22 PCL series, set the cameras t o HV-SYNC
reset mode.
CL-GE300 side 001 001
CL1 IN, CL2 IN, CL3 IN-Trigger IN 0
002 000 8bit
003 000 MONO
004 003 CL1 IN, CL2 IN, CL3 IN Synchronized OUT
©2009 CIS Corporation. All rights reserved.
12