9. Function Settings
With serial communications via LAN or 12pins circular connector RS-232C port, both cameras and
CL-GE 300 functions can be set.
(1) Serial communication settings are as follows.
Baud rate
: 9600bps
Data
: 8bit
Stop bit
: 1bit
Parity
: None
XON/XOFF : not controlled
(2) Control code
・ The total control code is 14 bits, which conforms to ASCII code.
・ The control code consists of camera No. process code, remote controller address, remote
controller data, and CR. Execute Read/Write through PC, and the camera will reply the data.
1 2 3 4 5 6
7th Byte
8 9 10 11 12 13 14
Camera No. Process code Remote
controller
address
Remote
controller data
CR
000000 : to CL1 IN
100000 : to CL2 IN
200000 : to CL3 IN
300000 : to all (CL1 IN/2 IN/3 IN)
400000 : to CL-GE300
“R” Read mode Please refer to
the address
table, in Section
5.
000~255
0Dh
“W” Write mode
“C” Camera mode
10. Initial Settings
Functions Address Data
Internal Trigger Cycle 000 0:OFF
Trigger Input Selection 001 0:CL1 IN-Trigger IN 0,CL2 IN-Trigger IN 1,CL3 IN-Trigger IN 2
10bit/8bit Selection 002 0:8bit
RGB/MONO(RAW) Selection 003 0:MONO(RAW)
Output Channel Selection 004 0:CL1 IN OUT